Submersible Pump Selection and Sump Design: Choosing the Impeller and Sizing the Sump Together

Submersible Pump Selection and Sump Design: Choosing the Impeller and Sizing the Sump Together

A submersible pump can be perfectly selected on paper and still fail early if the sump around it is wrong. The impeller decides what the pump tolerates, and the sump decides how often it starts, whether it draws air, and whether solids settle where the pump cannot reach them. This article covers the submersible pump vortex vs single channel decision, dewatering pumps, and the sump rules that go with them.

Three Pump Types, Three Duties

SCM submersible pumps come in three families: a vortex type (EPV.40H and EPV.40V), a single channel type (EPC.80), and a dewatering submersible pump type (EPD.65_F125). The duty details below are general and should be checked against the data sheet of the selected model.

TypeTypical useMain trade-off
Vortex impellerWastewater with solids or sandLower efficiency than a channel impeller
Single channel impellerRaw wastewater and sewage with larger solidsHigher efficiency, but the vane edge can catch stringy material
Dewatering pumpDrainage and dewatering dutyGenerally not intended for sewage; check the solids limit on the data sheet

Submersible Pump Vortex vs Single Channel: The Trade-Off

Grundfos describes the benefit of a vortex impeller over a channel impeller as a minimized risk of clogging, and notes that it is also the better choice when the liquid has a high sand content. The cost is efficiency: a pump with a vortex impeller is typically less efficient than one with a channel impeller. A vortex impeller pump is therefore the safer choice for difficult liquid, and a channel pump saves energy on cleaner duty where clogging risk is low.
Submersible Pump Vortex vs Single Channel: The Trade-Off

Clogging Is Not Only About Solids Size

It is common to select based on free passage through the impeller. A Xylem report on clogging argues that throughlet size alone does not determine clog resistance, because large hard objects are rare in wastewater compared with small hard particles and soft stringy material. Xylem also states that stringy material tends to be caught on single-vane and vortex impellers even when the throughlet is large. This is a manufacturer study of its own designs, so it is best read as a caution. The takeaway is to ask the supplier how the impeller handles rags and fibers, and not only the maximum solid size.

Clogging has two effects: partial clogging, which lowers flow and efficiency and raises power draw, and hard clogging, where the current exceeds the trip setting, and the pump stops.

Sump Volume and Starts per Hour
Sump Volume and Starts per Hour

Sump pump sizing starts with the motor: every pump start stresses it, so the sump has to give the pump enough running time between starts. A common design approach sizes the active volume from the minimum cycle time. A Seattle Public Utilities worked example for a small station uses a maximum of 6 motor starts per hour and a minimum motor cycle time of 10 minutes, and its result is consistent with an active volume of V = t × Q / 4, with V in gallons, t the cycle time in minutes, and Q the pump flow in gpm.

For example, a 10-minute cycle and a 100 gpm pump give V = 10 × 100 / 4 = 250 gallons of active volume between the start and stop levels. The factor 4 comes from the worst case in which inflow is half of the pump capacity. In SI units, the same rule is V = 0.9 × Q / Z, with V in m³, Q the pump flow in L/s, and Z the maximum starts per hour; for Z = 6 and Q = 6.3 L/s (about 100 gpm), V ≈ 0.95 m³, the same 250 gallons. This is a design example and should be checked against the applicable project standard. The motor manufacturer limit on pump starts per hour for the actual motor takes priority, and a second check on emergency storage can govern the volume instead of the cycle time.

The opposite limit matters as much. US design standards such as the Illinois rules limit the wet-well filling time at design average flow to 30 minutes, unless the facility is designed to provide flow equalization, to prevent septic conditions. In Saudi Arabia, warm sewage turns septic faster, so an active volume oversized “to be safe” trades fewer motor starts for hydrogen sulfide, odour, and concrete corrosion. Check both limits.

Submergence and Vortices

Minimum submergence is the vertical distance from the liquid surface to the pump inlet. It adds to available NPSH and prevents air-entraining vortices. The Hydraulic Institute relationship (ANSI/HI 9.8) for a vertical pump with a suction bell is S = D × (1 + 2.3 × F), where F = V / (g × D)^0.5, V is the inlet velocity, and D is the bell outside diameter. Required submergence rises with velocity, and it may need to be increased to satisfy the pump NPSH required.

Cornell Pump notes a rule of thumb of at least 5 times the suction pipe diameter, but states that it is often insufficient. Low submergence can cause air intake, loss of prime, noise, vibration, reduced flow, and cavitation damage. For a submersible pump, use the manufacturer minimum submergence for the model and treat the lowest stop level as a hard limit. Check the motor duty rating as well: some submersible motors are rated for continuous duty only when submerged or fitted with a cooling jacket, so the stop level may need to cover the motor, not only the pump inlet.

Sump Geometry

Wet well design also covers the floor. Texas wastewater rules (30 TAC §217.60), as one published example, require a wet well floor with a smooth finish and a minimum slope of 10% toward the pump intake, so that solids move to the pump instead of settling. Other codes are stricter: the Illinois rules require a minimum 1:1 slope to the hopper bottom, and the Wisconsin DNR lift station design checklist asks for the same, so 10% should not be copied as a universal figure. Project requirements in Saudi Arabia may differ, so the project specification and applicable code should be checked.
Sump Geometry

Practical Engineering Considerations

  1. Define the liquid: sewage, grey water, drainage, sand, or fibers.
  2. Choose the impeller family from the clogging risk and the energy trade-off.
  3. Confirm duty point, solids passage, and the manufacturer’s limit on the data sheet.
  4. Size the active volume from the cycle time and check emergency storage and maximum fill time.
  5. Set the stop level above minimum submergence and check NPSH and motor cooling.
  6. Give the floor a slope to the pump and avoid dead zones.
  7. Record the real starts per hour after commissioning and compare with the design.

The EQPT Perspective

EQPT supplies SCM submersible pumps in vortex, single-channel, and dewatering versions. Selecting the pump family is easiest when the liquid, the sump geometry, and the control levels are defined together, the same way component compatibility is checked across a whole treatment system.

Key Takeaways

  • Vortex impellers reduce clogging risk and tolerate sand, at the cost of efficiency.
  • Throughlet size alone does not determine clog resistance; ask how the impeller handles fibers.
  • Size the active volume from the cycle time, and let the motor manufacturer’s start limit govern.
  • Use the manufacturer’s minimum submergence and treat the stop level as a hard limit.
  • Check the real starts per hour after commissioning.
  • Do not oversize the sump: long fill times make warm sewage septic.

Conclusion

Choose the impeller for the liquid, size the sump for the motor, and set the levels for submergence. Treating these as one design avoids the clogging, air entrainment, and short cycling that cause most early failures of submersible pumps.

EQPT’s technical team can help review the liquid description, inflow, and sump dimensions against the SCM submersible pump range. Contact EQPT to discuss your pump and sump selection.

FAQ

Q: Is a vortex pump always the right choice for sewage?
No. It lowers clogging risk but costs efficiency. For fibrous raw sewage, ask how each impeller handles stringy material.

Q: How many starts per hour is acceptable?
The motor manufacturer’s limit governs. A utility design example uses 6 per hour with a 10-minute minimum cycle for a small station.

Q: Can a dewatering pump be used in a sump?
Only if the liquid is clean enough for it. Check the solids limit on the data sheet.

Q: How deep must a pump be submerged?
Use the manufacturer’s minimum submergence for the model. A rule of thumb of 5 times the suction diameter is often insufficient.